Cable News Alerts (CNA)- The Leading Source of Industry News on Power Cables and Cable Insulation
NEWSMAKERS: * Borealis * Borlink™ * ExcelPlas * Nexans * NKT * Prysmian * Sumitomo Electric * XLPE
INDUSTRY NEWS
Scottish Energy Company Investigates Blackout Caused by Subsea Cable Failure
https://www.theguardian.com/business/2020/oct/22/scottish-energy-company-ssen-investigates-blackout-caused-by-subsea-cable-failure
Nexans Cable-Lay Vessel Launched in Norway
https://www.offshore-mag.com/rigs-vessels/article/14187019/nexans-cablelay-vessel-launched-in-norway
NEW PATENTS
BOREALIS AG Patents Polymer Composition and Cable with Advantageous Electrical Properties
https://www.freepatentsonline.com/10822478.pdf
CABLE FAILURE & PREVENTION
Study on Identification of Defect Types in XLPE Cables
https://iopscience.iop.org/article/10.1088/1742-6596/1659/1/012040/pdf
Hybrid Technique Based Voltage Stabilizers for XLPE Cable Insulation
Cross-Linked Polyethylene (XLPE) power cable is commonly used as the medium for transmitting power supply in the power system network. However, frequent exposure of XLPE cable to the high voltage causes its insulation to degrade over time leading to electricity outages. Electrical treeing is a commonly observed phenomenon associated with dielectric breakdown in solid dielectrics.
http://solidstatetechnology.us/index.php/JSST/article/view/2855
Several Reasons for the Ageing of Polymer Cables
http://www.zonegemma.org/category/material-evaluation/
Material Development Approach for Injection Moulding Rejuvenation for Cable Insulation Failure [PDF]
https://iopscience.iop.org/article/10.1088/1742-6596/1639/1/012058/pdf
NEW RESEARCH
Enhancing the High Voltage XLPE Cable Insulation Characteristics Using Functionalized TiO2 Nanoparticles
http://www.sciencepublishinggroup.com/journal/paperinfo?journalid=316&doi=10.11648/j.ajpst.20200603.11
Degradation of Flame Retardance: A Comparison of EVA and LDPE Cables With Two Different Metal Hydroxides
https://onlinelibrary.wiley.com/doi/full/10.1002/app.50149
Thermal Oxidation of Cross-linked PE and EPR used as Cable Insulation Materials: Multi-Scale Correlation over a Wide Range of Temperatures
https://www.sciencedirect.com/science/article/pii/S0142941820321425
Examining Impact of Vapor-Induced Crosslinking Duration on Dynamic Mechanical and Static Mechanical Characteristics of Silane-Water Crosslinked Polyethylene Compound
https://www.sciencedirect.com/science/article/pii/S0142941820321620
Extended Thermal Rating Calculations of 400 kV XLPE cables for Urban Grid Applications Based on Long-Term Experimental Data
https://link.springer.com/article/10.1007/s00502-020-00841-6
Graphene Enhanced Electrical Properties of Polyethylene Blends for High-Voltage Insulation
https://link.springer.com/article/10.1007/s13391-019-00158-3
TESTING
This Newsletter is brought to you by the Australian Cable Material Testing Laboratory (NATA Certified)
ExcelPlas Cable Insulation Testing Laboratory Capabilities:
- DSC Thermal Analysis to identify melting point, Glass transition (Tg) and Thermal Stability (OIT)
- FTIR Infra-red Analysis for compositional analysis of polymers and additives
- TGA Thermogravimetric Analysis for weight loss with loss of additives, oils, polymer decomposition, filler levels
- X-Ray Analysis (EDS/XRD) to identify the crystalline phase and composition of inorganic additives
- Carbon Black Content (ASTM D1603, AS/NZS 2904 Clause 7.4.5 which uses AS 1463 Appendix B)
- Carbon Black Dispersion
- Oxidative Induction Time (OIT)
- Melt Flow Index (MFR)
- Stress Cracking Resistance Testing (ESCR testing)
- Failure Analysis (processing, water treeing, contamination ID, etc)
Examples of Polymer Materials Excelplas Can Test:
XLPE and HDPE Cable Insulation Testing (QA, QC, incoming raw materials)
- PVC (V-90) (Soft (plasticised) Polyvinyl Chloride compound)
- XLPE (X-90, X-HF-110) (Crosslinked Polyethylene)
- Rubber (R-EP-90, R-HF-90, R-HF-110) (Ethylene Propylene Rubber)
ExcelPlas Undertakes the Following Cable Testing as per AS/NZS 5000 and AS/NZS 3808:
- Measurement of thickness of insulation and sheath (sample test)
- Tensile strength and elongation of insulation and sheath material – before ageing (type test)
- Tensile strength and elongation of insulation and sheath material – after ageing (type test)
- Loss of mass of insulation and sheath (thermoplastic materials only) (type test)
- Pressure test at high temperature of insulation and sheath (thermoplastic materials only) (type test)
- Heat shock (thermoplastic materials only) (sample test)
- Hot set test (cross linked materials only) (type test)
- Exudation of plasticizer (thermoplastic materials only) (type test)
- Compatibility test of cables materials (type test)
Other Cable and Insulation Testing Offered by ExcelPlas NATA Labs:
- Shore A/D Hardness
- Density Determination
- Accelerated Weathering testing
- Charpy and Izod Tensile Tester
- Laboratory press for preparing samples
- Plasticizer extraction analysis apparatus
- Loss in Mass (volatility) analysis
- Limiting Oxygen Index (LOI) Analysis of Cables
- Wire Insulation Abrasion
- Testing Composition of Low Smoke Zero Halogen Cables
- Testing of %Crosslinking of XLPE Cables
- Testing of Tree Retardant XLPE Cables
- Identification of Contamination/Foreign Matter
- Determination of % Carbon Black in Cable Sheathing
- Determination of Filler Content/Composition in Cable Insulation
- Limiting Oxygen Index of Flame Retardant Cables
- Plasticizer Level and Content of PVC Insulated Cables
- Compliance Testing of Important Cable to Ensure it is Compliant with Australian Standards
Copyright 2020 Cable News
https://www.cablenewsaustralia.com.au
More Cable News
http://www.cablenewsaustralia.com.au/
Cable News Alerts is a leading international Wire and Cable news and online newsletter platform for wire and cable manufacturing companies.
This Newsletter is brought to you by the Australian Cable Material Testing Laboratory (NATA Certified)
ExcelPlas Cable Insulation Testing Laboratory Capabilities:
-DSC Thermal Analysis to identify melting point, Glass transition (Tg) and Thermal Stability (OIT)
-FTIR Infra-red Analysis for compositional analysis of polymers and additives
-TGA Thermogravimetric Analysis for weight loss with loss of additives, oils, polymer decomposition, filler levels
-X-Ray Analysis (EDS/XRD) to identify the crystalline phase and composition of inorganic additives
-Carbon Black Content (ASTM D1603, AS/NZS 2904 Clause 7.4.5 which uses AS 1463 Appendix B)
-Carbon Black Dispersion
-Oxidative Induction Time (OIT)
-Melt Flow Index (MFR)
-Stress Cracking Resistance Testing (ESCR testing)
-Failure Analysis (processing, water treeing, contamination ID, etc)
http://excelplas.com/
Examples of Polymer Materials Excelplas Can Test:
XLPE and HDPE Cable Insulation Testing (QA, QC, incoming raw materials)
* PVC (V-90) (Soft (plasticised) Polyvinyl Chloride compound)
* XLPE (X-90, X-HF-110) (Crosslinked Polyethylene)
* Rubber (R-EP-90, R-HF-90, R-HF-110) (Ethylene Propylene Rubber).
ExcelPlas Undertakes the Following Cable Testing as per AS/NZS 5000 and AS/NZS 3808:
* Measurement of thickness of insulation and sheath (sample test)
* Tensile strength and elongation of insulation and sheath material – before ageing (type test)
* Tensile strength and elongation of insulation and sheath material – after ageing (type test)
* Loss of mass of insulation and sheath (thermoplastic materials only) (type test)
* Pressure test at high temperature of insulation and sheath (thermoplastic materials only) (type test)
* Heat shock (thermoplastic materials only) (sample test)
* Hot set test (cross linked materials only) (type test)
* Exudation of plasticizer (thermoplastic materials only) (type test)
* Compatibility test of cables materials (type test)
Other Cable and Insulation Testing Offered by ExcelPlas NATA Labs:
• Shore A/D Hardness
• Density Determination
• Accelerated Weathering testing
• Charpy and Izod Tensile Tester
• Laboratory press for preparing samples
• Plasticizer extraction analysis apparatus
• Loss in Mass (volatility) analysis
• Limiting Oxygen Index (LOI) Analysis of Cables
• Wire Insulation Abrasion
• Testing Composition of Low Smoke Zero Halogen Cables
• Testing of %Crosslinking of XLPE Cables
• Testing of Tree Retardant XLPE Cables
• Identification of Contamination/Foreign Matter
• Determination of % Carbon Black in Cable Sheathing
• Determination of Filler Content/Composition in Cable Insulation
• Limiting Oxygen Index of Flame Retardant Cables
• Plasticizer Level and Content of PVC Insulated Cables
• Compliance Testing of Important Cable to Ensure it is Compliant with Australian Standards
Copyright 2020 Cable News